Hiltra

Rental of F90 safety cabinets

Model specifications
Article number 311311311
Certification F90 according to NEN-EN 14470-1
External WxDxH 1200 x 600 x 2135 mm (H= including bottom plinth)
Internal WxDxH 1095 x 450 x 1824 mm
Fixture (standard) 3x adjustable shelf, 1x bottom tray incl. insertion grid
Shelf WxDxH 1070 x 420 x 30 mm
Bottom tray BxDxH 1093 x 440 x 100 mm
Contents bottom tray approx. 37.5 liters
Material and color furnishings Steel powder coated RAL 7035/light grey
Material and color cabinet body Steel powder coated RAL 7035/light grey
Double wing door Self-closing and lockable
Weight 375 kg

Article number 311311311
Certification F90 according to NEN-EN 14470-1
External WxDxH 1200 x 600 x 2135 mm (H= including bottom plinth)
Internal WxDxH 1095 x 450 x 1824 mm
Fixture (standard) 3x adjustable shelf, 1x bottom tray incl. insertion grid
Shelf WxDxH 1070 x 420 x 30 mm
Bottom tray BxDxH 1093 x 440 x 100 mm
Contents bottom tray approx. 37.5 liters
Material and color furnishings Steel powder coated RAL 7035/light grey
Material and color cabinet body Steel powder coated RAL 7035/light grey
Double wing door Self-closing and lockable
Weight 375 kg

General specifications

Version 1.3 | 25-11-2019

F90 Labsaver® safety cabinet model LS1220-EN

A safety cabinet purchased after 1 January 2006 must comply with European standard EN 14470-1/2004, fire resistance 30, 60 or 90 minutes, in accordance with PGS15. A product certificate must be available within the establishment for the safety cabinet which shows that it meets the aforementioned European standard. The instructions containing the certificates are supplied with the Labsaver cabinet.

Design/fire resistance:
  • Design and layout in accordance with the regulations in the PGS 15 guideline.
  • Cabinets are only suitable for indoor use.
  • Fire resistance 90 minutes determined in accordance with the European Norm (NEN-)EN 14470-1/2004 by accredited test institute MPA Dresden.
  • Tested according to the European Standard EN 14727 (Laboratory furniture).
  • GS mark "Geprüfte Sicherheit" issued by the accredited test institute MPA Dresden.
  • CE declaration of conformity according to the European Standard EN 45014.
  • Internal panelling: Formaldehyde emission class E1 to EN 13986; biological risk class 1 to EN 335-3; fire class B-s2,dO to EN 13501-1:2002.
Enclosure:
  • Enclosure body and door manufactured from zincor steel and powder coated in RAL 1007/carnic yellow ( n/a on LS320) or RAL 7035/light grey.
  • Fire resistant insulation package made of non-combustible, environmentally friendly materials finished with a white impact and scratch resistant HPL top layer.
  • Potential-free earthed on the enclosure body up to the earthing connection point on the enclosure roof.
  • The interior of the cabinet is optionally earthed up to the earthing connection point on the roof of the cabinet.
  • Standard with adjustable feet ±20 mm for leveling the cabinet. (not available on LS320)
Door:
  • Front equipped with a single or double self-closing wing door with a handle placed at an ergonomic height and lockable by means of a cylinder lock (incl. 2 keys).
  • Door optionally available with thermolock fire door closing mechanism so that it can remain open in a position of 90º to 100º, but closes automatically in case of fire.
  • Door rebate provided with fire resistant strips, so that the door rebate is hermetically closed in case of fire.
Fixture:
  • Fixture manufactured from zincor steel and powder coated in RAL 7035/light grey.
  • Equipped with a freely removable, liquid-tight container with removable insert, load-bearing capacity 75 Kg.
  • Note: according to the NEN-EN14470-1, a floor collector without insertable grid may not be used as a set-up/storage area for packaging.
  • Side walls of the cabinet are fitted with steel powder coated shelf fixing plate with hook-in grid for the shelves with a height adjustment in a grid of 50 mm. ( n.a. for LS320-EN).
  • Shelf fixing plate also serves as liquid guiding plate.
  • Fitted with 3 freely removable shelves with 30 mm high skirting boards as protection against sliding, load capacity 75 kg with evenly distributed load. ( not applicable for LS320).
Ventilation openings:
  • Fitted in the rear wall with an integrated ventilation and venting channel.
  • Ventilation opening in the enclosure, 1 x above the bottom drip tray (low) and 1 x ventilation opening in the rear wall (high).
  • Ventilation duct provided with fire dampers which close automatically in case of fire.
  • Ventilation openings on the rear wall (LS320-EN) or on the roof (LS620-EN and LS1220-EN) provided with flange
  • Ø 80 x H 65 mm for the constructional connection to a ventilation system or optional cabinet fan.
Hazard identification:
  • Hazard indication by means of the type label prescribed in EN 14470-1 with pictograms, symbol: "smoking and open flame prohibited" and "flammable substances".


Offers
Bigsaver F60 model BS 3/2700 (occasion)
Promotion price
€ 7.927,40
Labsaver F90 LS1220-EN - yellow
Promotion price
€ 2.341,60
Labsaver F90 LS620-EN - yellow
Promotion price
€ 1.910,45